C1303 operation manual Page 1 1. Introduction C1303 is a microcomputer controller to control both temperature and humidity, with the following input and output: l Temp.and humidity sensor(HP) l Temp.-control relay K1 (16A 250VAC) l Humidity-control relay K2 (10A 250VAC) 2. Error status: 1.E-T error in temp. 2.E-H error in humidity. 3.PrE error in parameter. Enter parameter menu and select dFu; then select 1 to restore to its default. Then reset the parameter. 4.L-t temp. is lower than the lowest alarm temp.(LSt). 5.L-H humidity is lower than the lowest alarm humidity.(LSH). 6.H-t temp. is higher than the highest alarm temp.(USt). 7.H-H humidity is higher than the highest alarm humidity.(USH). 3. 1 Panel SET: In programming mode, it is used to select the parameter to set or to confirm programming operation. Press SET, controller will display set humidity.(sp); Press SET for 6 seconds to set up the set humidity value(sp); ▲(UP): browse parameters or add parameters in programming mode. ▼ (DOWN): browse parameters or reduce parameters in programming mode. Combination key: ▲ + ▼ lock or unlock the keyboard SET +▲ press them simultaneously and enter the mode of parameter setting 3.2 LED status LED status Function on temp.-control relay(K1) is on on Humidity-control relay(K2) is on T on Controller displays temperature T off Controller displays humidity SET on Set status 3.3 Check and modify set temperature(SPt) 1. Press SET and then relax, it will display SPt; 2. Press SET for 6 seconds, it will display set temperature(SPt) in flash; 3. Press▲or▼to modify SPt; 4. Press SET again to save SPt and return to its display mode. If there is no press in 10 seconds,controller will return to its display mode. 3.4 Check and modify set humidity(SPH) 1. Press and then relax at once, it will display SPH; 2. Press for 6 seconds, it will display set humidity (SPH) in flash; Temp. output Set Humidity output Display status C1303 operation manual Page 2 3. Press▲or▼to modify SPH 4. Press SET to save SPH and return to its display mode; if there is no display in 10 seconds,controller will return to its display mode. 3.5 How to modify parameters 1. Press combination key SET+▲ for 6 seconds to enter parameter management; 2. Press▲or▼ to select parameters to set; 3. Press SET it will display the selected parameter; 4. Press▲or▼to change parameters; 5. Press SET to store the modification and return to parameter management; 6. Select End or there is no press in 10 seconds, controller will return to display mode. 3.6 How to lock and unlock keyboard 1. Press combination key▲+▼for 3 seconds to lock and unlock keyboard; 2. If keyboard is locked, controller will display OFF; if keyboard is unlocked, controller will display ON. 4. Parameter table Ust: up-limit of temp.. range: -19.9-100C, default: 100C. UsH: up-limit of humidity. range: 0.1-100%RH, default: 100%RH. Lst: low-limit of temp. range: -20.0-99.9C, default: -20.0C. LsH: low-limit of humidity. range: 0.0-99.9%RH, default: 0%RH. CAt: temp. sensor compensation. range:-10.0-10.0C default: 0.0C CAH: humidity sensor compensation range: -10.0-10.0%RH default: 0.0%RH HSt: temp. control hysteresis range: 0.1-20.0C default: 1.0C HSH: humidity control hysteresis range: 0.1-20.0%RH default: 3.0%RH HAt: temp.-alarm control hysteresis default: 0.1-20.0C default: 1.0C HAH: humidity-alarm control systersis default: 0.1-20.0%RH default: 3.0%RH C-H: temp. control mode range: 0-1 default: 1 0 cooling mode 1 heating mode * C-H is set as 0. When temp. is higher than SPt, temp. control relay K1 will open; when temp. drops to sp –HSt, temp. control relay K1 will shut off. * C-H is set as 1; When temp. is lower than SPt, temp. control relay will open; when temp. rises to sp + HSt, temp. control relay K1 will shut off. d-H: humidity control mode range: 0-1 default: 1 0 dehumidity mode 1 humidity mode * d-H is set as 0. When humidity is higher than spH, humidity control relay K2 will open; when humidity drops to spH–HSH, humidity control relay K2 will shut off. * d-H is set as 1. When humidity is lower than spH, humidity control relay K2 will open; when humidity rises to spH+HSH, humidity control relay K2 will shut off. S-t: switching period of temp. and humidity range: 1-255 seconds default: 5 seconds S-H: display mode range: 0-2 default: 0 0 display temp. or humidity according to S-t 1 display temp. only 2 display humidity only dFu: range: 0-1 1 return to default 0 no change END: parameter setting is finished. C1303 operation manual Page 3 5.. figure 6. Technical data: Case: ABS, black Size: 75x38x70 Mounting hole: 71x29.5 Protective class: panel, IP54 Connection: screw Working condition: -10℃~55℃, RH<85%, no defrosting Storage condition: -10℃~70℃, RH<85%, no defrosting Measuring range: temperature, -20~100C Humidity: 0~100%RH(related to humidity sensor) Sensor measuring environment: related to sensor type e.g.: DB111 temperature: -20~60C, humidity: 0~100%RH DB113 temperature: -20~100C, humidity: 0~100%RH Display accuracy: 0.1 Power: 220VAC,±10%,50/60Hz Power consumption: lower than 2W Relay: K1 250VAC, 16A K2 250VAC, 10A Sensor: DHT6x series Input: four keys Output: 2 relays Display: 3-digit LED Connection Fig. data sck Controller Sealing Panel Bracket Comm. CONTROLLER 10A(MAX) 16A(MAX) 250VAC 250VAC Power 220VAC/50Hz K1 DHT65 DHT6X 4 5 K2 humidity Temp. 1 2 3 4 5 6 5 7 8 9 Vcc Gnd
80.48 USD InStock
TripleClicks is the home of 12,188,768 Members in 195 countries worldwide!

Create an account

NOTE! By submitting this registration, you are acknowledging that you have read and agree to the TripleClicks Privacy Policy.

Join FREE today

Account created

You're now a TripleClicks member! Now is a great time to get some ZCredits, which are used to bid on Pricebenders auctions, play Eager Zebra games and more!

Continue to TripleClicks

Get some ZCredits now!

What are ZCredits? They're used for bidding in Pricebenders™ auctions, playing Eager Zebra™ games, downloading TC Music, listing stuff you no longer need for sale at TripleClicks, and more! Learn more about ZCredits.

Billing Info

Payment Info

ORDER TCREDITS MAYBE LATER

50 ZCredits are now in your account--ready for you to use! We've also dispatched a quick order confirmation email to you. Thank you!

CONTINUE TO TRIPLECLICKS
The requested item is no longer active.